  • Time: 2019-05-12 22:19:54

Zero Loss  Blower Heater Adsorption Compressed Air Dryer


Descriptions

Blower purge desiccant compressed air dryer uses air blower and external electrical heater to produce purge air for desiccant regeneration.

The blower intakes atmospheric air flow through the heater, then through the desiccant media thereby regenerating it. With this design, no dried compressed air is consumed for regeneration, which maximizes the amount delivered to the air system. Blower heater Air Dryer is usually suitable for large flow from 23 -510m3/min ,outlet air pressure dew point is -40°C.


Standard Features

High Performance pneumatic Valves

Oil-less pneumatic valves are designed specifically for high temperature applications and feature stainless steel internals and filled PTFE seats.

Low wattage heater with high temperature interlock

Low-wattage high incoloy sheathed heater for efficient regeneration.

Heater high temperature with interlock alarm provides continuous monitoring of heater sheath temperature. The heater will de-energize in a high temperature condition.


High Efficiency Centrifugal Blower

Reliable, quiet generation of purge air. Intake filter is positioned for convenient access to facilitate filter element changeout.

High performanced desiccants

Double fixed bed layers, respectively filled with high performanced activated alumina and molecular sieve.

Advanced PLC controller

PLC Controlling system executes and monitors all dryer functions, 7" Touch screen panel displays dryer status.

5068940.webp---副本.jpg

Dew Point Display

Highly accurate ceramic dew point sensor and high dew point alarm.

Pressure Gauges

Stainless steel gauges, located on each tower, provide visual indication of pressure during drying and regeneration processes.

Large Purge Mufflers

Large mufflers minimize noise and include built-in safety relief valves.

Model   Flow  Capacity Heater (kw)BlowerInlet/outlet ConnectionDimensionsWeight
m3/minCFM(kw)L(mm)W(mm)H(mm)(kg)
TOP-20023812153.3DN801560163027801380
TOP-25027953184.2DN801870183028801720
TOP-300341200245.5DN802090199030702060
TOP-40045158832.47.2DN1002530218029202750
TOP-500551941428.8DN1002750239031003430
TOP-6006522944810.8DN1252920251030804120
TOP-80087307164.813.8DN1503040278031205500
TOP-100011038838117.5DN1503210292032006300
TOP-1200130458995.420.8DN1503380308032807810
TOP-15001605648119.725.8DN2003520318034109200
TOP-2000210741316234.5DN20036803320356011300
TOP-25002609178205.243.2DN25037203400364014000
TOP-30003201094324051.8DN25038203480372014900
TOP-35003601270828559.2DN30039503560381016200
TOP-4000410144731867.8DN30045203720389017900
TOP-50005101800339878.2DN35053803980397019200